cover
Contact Name
Dr. Remon lapisa
Contact Email
remonlapisa@ft.unp.ac.id
Phone
+6281285228440
Journal Mail Official
invotek@ppj.unp.ac.id
Editorial Address
Jalan Prof. Dr. Hamka Air Tawar Padang 25131
Location
Kota padang,
Sumatera barat
INDONESIA
INVOTEK: Jurnal Inovasi Vokasional dan Teknologi
ISSN : 14113414     EISSN : 25499815     DOI : -
INVOTEK: Jurnal Inovasi Vokasional dan Teknologi is a double blind peer-reviewed journal for Technical, Vocasional, Education and Training (VET) related research. This journal provides full open access to its content on the principle that making research freely available to the science community and the public supports a greater global exchange of knowledge and the further development of expertise in the field of Vocational Education and Training (understood in a wide sense and also known as e.g. TVET Technical Vocational Education and Training, Professional Education and Training, Career and Technical Education, Workforce Education).
Arjuna Subject : Umum - Umum
Articles 7 Documents
Search results for , issue "Vol 22 No 1 (2022): INVOTEK: Jurnal Inovasi Vokasional dan Teknologi" : 7 Documents clear
Heutagogy: Empirical study on conceptual understanding, self-learning awareness and learning outcomes Rinaldi Rinaldi; Deni Wahyuni; Isa Hamzah
invotek Vol 22 No 1 (2022): INVOTEK: Jurnal Inovasi Vokasional dan Teknologi
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/invotek.v22i1.986

Abstract

Some problems are attached by the online learning system such as low self-learning awareness and conceptual understanding. One of the learning approaches is the concept of heutagogy which is the development of andragogy approach. Self-learning awareness and conceptual understanding are needed either online or offline learning system, so it can improve student learning outcomes in all subjects. However, previous studies on the effect of the heutagogy approach on self-learning awareness and conceptual understanding as well as relate it to increase learning outcomes is still limited. Likewise with research on how the influence of self-learning awareness, conceptual understanding and their interaction on increasing learning outcomes has not been found. As novelty, this study aims to determine the effect of the heutagogy approach on increasing conceptual understanding and self-learning awareness and the interaction effect of self-learning awareness and conceptual understanding on course learning outcomes. This study is quasi-experiment. A total of 250 first-year students were randomly selected as samples in the pre-test and post-test. Data were collected by distributing a set of questionnaires and a set of exams via Google forms and were analyzed using Statistical Package for Social Science 23.0 (SPSS v 23.0) and SmartPLS 3.0. Findings showed that the heutagogy approach has possitive and significant effect to increase conceptual understanding and self-learning awareness. Self-learning awareness has a positive and significant effect and also mediates the effect of conceptual understanding on learning outcomes. Heutagogy approach increase conceptual understanding (8.79%), self-learning awareness (10.68%), and learning outcomes (6.70%) compared with traditional method.
Structural assessment of building Elementary School 28 Air Tawar Timur Padang Prima Yane Putri; Candra Candra
invotek Vol 22 No 1 (2022): INVOTEK: Jurnal Inovasi Vokasional dan Teknologi
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/invotek.v22i1.920

Abstract

Abstract ˗˗The State Elementary School 28 Air Tawar Timur Padang is an Inpres School which was built in 1982. The current condition of the school building is damaged, such as cracks, loose concrete (spalling), deflection and shaking floors. This study aims to provide recommendations for repair or maintenance of the school building. The assessment method used in this study is the Non Destructive Test (NDT) method. Testing the compressive strength of concrete using a Schmidt Rebound Hammer. To see the amount of reinforcing steel, diameter of reinforcing steel and dimensions of structural elements using a Rebar Locator, Caliper, and a meter. Testing the building geometry and deflection floor plates using Total Station and Laser Measurement. The building structure was analyzed using the SAP2000 program. The results of the concrete compressive strength test (fc ') are on average 20.40 MPa on the column, 22.23 MPa on the beam, and 23.43 MPa on the floor plate. The results of visual observations of the building are categorized as severely damaged with the proportion of damage above 20%. Where the proportion level of column damage is 32%, beams 20.35%, and the floor court is 65%. The results of the building structure evaluation show that all elements are categorized as unsafe except Beams 3, Beams 4, and Column 2. The maximum deflection of the floor as high as 73 mm exceeds the allowable permit, which is 18.9 mm. The recommendation for repair of the school is building renovation.
Analysis of student’s learning outcomes test questions Department of Automotive Engineering FT UNP Hendra Dani Saputra; Sartika Anori; Donny Fernandez; Dedi Setiawan
invotek Vol 22 No 1 (2022): INVOTEK: Jurnal Inovasi Vokasional dan Teknologi
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/invotek.v22i1.964

Abstract

This study is a follow-up to the results of previous studies, which stated that e-learning media did not have a significant effect on improving learning outcomes. One way of measuring learning outcomes is by presenting test questions on E-Learning media. So that a good test item will be able to provide a good measurement of learning outcomes. This research is included in quantitative descriptive research. The research aims to see the level of validity, reliability, difficulty index and Different power test questions for students of the Department of Automotive Engineering, FT UNP. The research method presenting test items in the form of multiple choice. Then proceed with quantitative analysis of the test items. The results of the analysis will provide an overview of the criteria for valid items of 84% and the reliability index of the questions in the criteria of 0.899. The results of the test difficulty index analysis, that 80% of the test questions are included in the category of good test items. As many as 20% of the test questions including the category are too easy. The results of the analysis of the different power of the test items are 28% including the bad classification. Classification test questions are sufficient at 40%. Classification of different test items is good at 32%. The category of good test items is a category of test items with sufficient and good classification.
Numerical prediction of rotary-kiln foundation temperature at an early age Adek Tasri
invotek Vol 22 No 1 (2022): INVOTEK: Jurnal Inovasi Vokasional dan Teknologi
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/invotek.v22i1.1008

Abstract

The hydration heat confined to the core of the mass concrete during the hydration reaction causes a temperature rise and irregular temperature distribution in the concrete. High temperatures in concrete cause Delay Ettringite Formation (DEF) that cause damage several years after pouring, especially if the concrete is in an acidic environment. The uneven temperature distribution causes thermal stresses that can initiate cracks in the concrete surface. This article discusses a prediction of temperature distribution inside a mass concrete used as a rotary kiln foundation. We measure the heat of hydration of the concrete sample using an adiabatic calorie meter and derive the heat of hydration equation from the measurement data. The hydration heat was used in numerical calculations to obtain the temperature distribution, maximal temperature and temperature differential. The numerical calculation shows that the maximum foundation temperature was 64.01 0C. This temperature is still below the limit temperature for the occurrence of Delayed Ettringite Formation (DEF). The core region has the highest temperature, while the surfaces have the lowest temperature. The difference between the highest and lowest temperatures is 37.40 0C. However, the temperature differential exceeds the safe limit, 20 0C, so heat treatment to prevent cracking needs to be done.
Analysis of Contractor's Knowledge Level about Construction Safety Management System Budget Plan Components (Case Study: Construction Project in Padang City) Prima Zola; Viola Paramita Susanti; M. Giatman; Annisa Prita Melinda; Fitra Rifwan
invotek Vol 22 No 1 (2022): INVOTEK: Jurnal Inovasi Vokasional dan Teknologi
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/invotek.v22i1.954

Abstract

Work accident prevention is cheaper than responding responsively after an accident. Common problems are weakness and a lack of predicted levels of risk for a job that could potentially be a work accident. Risk Control is undoubtedly something that must be designed before the work is done. This control must be supported by costs to run a Construction Safety Management System (SMKK). The initial observations and references that have been conducted and collected indicate the problem that the financing does not appear in the Budget Plan of the contractors in several construction projects when participating in the tender auction at the research site, namely: The City of Padang. There are limitations of information media, socialization, and implementation instructions become challenges in running it. This fundamental problem gave rise to an idea to carry out research. This research has been conducted to explore the problem of the level of knowledge of contractors about the financing of smkk. The data in this study was obtained by survey, in detail, disseminating questionnaires online to samples, namely: contractors in the city of Padang. The questionnaire has been analyzed, resulted the level of knowledge of this contractor is quite good in the level of knowledge about the components of the budget plan of SMKK. There is no problem with the contractor's knowledge related to the budget plan, except: readiness and planning for the system of budget.
A Finite Element Analysis of Structural Strength of Ferry Ro-Ro’s Car Deck M. Uswah Pawara; Alamsyah Alamsyah; Rodlian Jamal Ikhwani; Ade Ray Siahaan; Andi Mursyid Nugraha Arifuddin
invotek Vol 22 No 1 (2022): INVOTEK: Jurnal Inovasi Vokasional dan Teknologi
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/invotek.v22i1.959

Abstract

Ferry Ro-Ro is a type of ship used to carry passengers and vehicles. This ship has several decks such as navigation decks, passenger decks, and car decks. The car deck is subject to a heavy load as it should accommodate vehicle loads. This study aims to conduct a finite element analysis to determine the stress and deformation experienced on the car deck of the Ferry Ro-Ro and determine the safety factor based on BKI (Indonesian Classification Bureau). The method used in this study is the Finite Element Method (FEM) which has been applied in the finite element based-applications namely Ansys Workhbench. The simulations are carried out using the software by varying the thickness of the car deck’s plate, the plate is subjected to pressure loads which are car loads accommodated by the car deck. Moreover, the fixed support is applied in the deck during the simulation. Based on the simulation results of variations of 90, 100, and 110% plate thickness. It is obtained that the smallest plate experienced maximum stress and the obtained safety factor of all plate thickness variations was satisfied the BKI Standard.
Evaluasi Displacement Horizontal Pasar Raya Padang Blok IV Berdasarkan Gaya Gempa Pada SNI-03-1732-2019 majid maulana; Eka Juliafad
invotek Vol 22 No 1 (2022): INVOTEK: Jurnal Inovasi Vokasional dan Teknologi
Publisher : Universitas Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24036/invotek.v22i1.930

Abstract

Pasar Raya Padang Market blok IV was built in 2016 as an resisting earthquake building based on SNI-1726-2012. The building has a building dilatation with a distance of 1 cm. The purpose of this study was to evaluate the dilatation distance of the Raya Padang Blok IV market building based on the seismic forces required in SNI-1726-2019.The evaluation method used in this research is numerical analysis method by using non-linier pushover over analysis. The numerical model used 3D model with the input material and the earthquake loading according to the proposed design and the response spctrum from SNI-1726-2019. This research evaluate overall structural performance of the buildings based on ATC-40. The results of the pushover analysis of the Raya Padang Blok IV Market building are the maximum displacement of the building of 9.936 mm, the allowable displacement is 320 mm, and the shear force to occur is 1409.094 KN, while the design shear force is 1508.3265. The results of this analysis conclude that the existing dilatation distance in the existing building meet the minimum requirement need based on this study. Building performance level reachs Immidiate Occupancy Level which means the building can be functioned immideately as the eartquake ends.

Page 1 of 1 | Total Record : 7